Physics, 12.10.2019 18:00 dbanks701

The main disconnect in a service panel is a(n)
a. ammeter.
b. bus bar.
c. receptacle.
d. circuit breaker.

ansver
Answers: 2

Another question on Physics

question
Physics, 22.06.2019 01:00
First, launch the video below. you will be asked to use your knowledge of physics to predict the outcome of an experiment. then, close the video window and answer the question at right. you can watch the video again at any point. part a as in the video, we apply a charge +q to the half-shell that carries the electroscope. this time, we also apply a charge –q to the other half-shell. when we bring the two halves together, we observe that the electroscope discharges, just as in the video. what does the electroscope needle do when you separate the two half-shells again? view available hint(s) as in the video, we apply a charge + to the half-shell that carries the electroscope. this time, we also apply a charge – to the other half-shell. when we bring the two halves together, we observe that the electroscope discharges, just as in the video. what does the electroscope needle do when you separate the two half-shells again? it deflects more than it did at the end of the video. it deflects the same amount as at end of the video. it does not deflect at all. it deflects less than it did at the end of the video. submit
Answers: 2
question
Physics, 22.06.2019 14:30
A10nc charge sits at a point in space where the magnitude of the electric field is 1500 n/c. what will the magnitude of the field be if the 10 nc charge is replaced by a 20 nc charge? assume the system is big enough to consider the charges as small test charges.
Answers: 1
question
Physics, 22.06.2019 15:50
Select all the correct answers. which changes will increase the rate of reaction during combustion? decreasing the area of contact between the reactants adding more oxygen to the reaction removing heat from the reaction changing the reactants from solid form to powdered form lowering the exposure of the reactants to air
Answers: 3
question
Physics, 22.06.2019 16:50
Acommercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -35°c by rejecting waste heat to cooling water that enters the condenser at 18°c at a rate of 0.25 kg/s and leaves at 26°c. the refrigerant enters the condenser at 1.2 mpa and 50°c. if the compressor consumes 3.3 kw of power, determine (a) the mass flow rate of the refrigerant, (b) the refrigeration load, (c) the cop, and (d) the minimum power input to the compressor for the same refrigeration load.
Answers: 2
You know the right answer?
The main disconnect in a service panel is a(n)
a. ammeter.
b. bus bar.
c. receptac...
Questions
question
Mathematics, 13.11.2020 20:10
question
Geography, 13.11.2020 20:10
question
Mathematics, 13.11.2020 20:10
Questions on the website: 13722363