A pressure gauge with a measurement range of 0-10 bar has a quoted inaccuracy of +1.0% f. s. (+1% of full-scale reading). (a) What is the maximum measurement error expected for this instrument? (b) What is the likely measurement error expressed as a percentage of the out reading if this pressure gauge is measuring a pressure of 1 bar?​

ansver
Answers: 3

Another question on Physics

question
Physics, 22.06.2019 05:10
Waves are used in many practical applications to support work, entertainment, and health. one example is the use of ultrasound imaging to safely track the development of a growing fetus. what is a specific example of a practical application of waves in medicine, entertainment, safety, or other fields? provide a brief explanation of how the properties of waves are useful to that application.
Answers: 3
question
Physics, 22.06.2019 07:20
Samir watches a 100-minute movie on his spaceship. maria's spaceshipe flies in the same direction as samir's spaceship but she observes his move to last 125 minutes and his spaceship to be 40 m long. how long does samir observe his own spaceship to be? according to an observer on earth, planet x is stationary. maria and samir depart earth on their spaceships at the same time, each flying at 0.5c. maria flies toward planet x and samir flies in the opposite direction. according to maria, her voyage to planet x takes 9 years. how many years does marias voyage take according to samir?
Answers: 3
question
Physics, 22.06.2019 10:30
Astone weighing 1.5 kilograms is resting on a rock at a height of 20 meters above the ground. the stone rolls down 10 meters and comes to rest on a patch of moss. the gravitational potential energy of the stone on the moss is joules.
Answers: 1
question
Physics, 22.06.2019 14:20
4r-134a enters the condenser of a residential heat pump at 800 kpa and 50°c at a rate of 0.022 kg/s and leaves at 750 kpa subcooled by 3°c. the refrigerant enters the compressor at 200 kpa superheated by 4°c determine (a) the isentropic efficiency of the compressor, (b) the rate of heat supplied to the heated room, and (c) the cop of the heat pump. also, determine (d) the cop and rate of heat supplied to the heated room if this heat pump operated on the ideal vapor-compression cycle between the pressure limits of 200 and 800 kpa. (0.757, 4.37 kw, 5.12, 6.18, 3.91 kw)
Answers: 3
You know the right answer?
A pressure gauge with a measurement range of 0-10 bar has a quoted inaccuracy of +1.0% f. s. (+1% of...
Questions
question
Social Studies, 02.10.2020 15:01
question
Mathematics, 02.10.2020 15:01
question
English, 02.10.2020 15:01
question
English, 02.10.2020 15:01
Questions on the website: 13722367