A mass spectrograph is used to measure the masses of ions, or to separate ions of different masses. In one design for such an instrument, ions with mass m and charge q are accelerated through a potential difference V. They then enter a uniform magnetic field that is perpendicular to their velocity and are deflected in a semicircular path of radius R. A detector measures where the ions complete the semicircle and from this it is easy to calculate R.

Derive the equation for calculating the mass of the ion from measurements of B, V, R, and q.

What potential difference V is needed so that singly ionized 12C atoms will have R=50.0 cm in a0.150-T magnetic field?

Do you think that this beam separation is sufficient for the two ions to be distinguished?

ansver
Answers: 3

Another question on Physics

question
Physics, 22.06.2019 16:10
To a of 4 x hz is 1. 0. mm nm nm
Answers: 1
question
Physics, 22.06.2019 21:50
Which of the following is part of the explanation or description of electromagnetic waves? (select all that apply) a. electrically charged molecules in a medium transfer their energy to nearby electrically charged molecules. b. a changing electric field causes a changing magnetic field. c. magnetic molecules in a medium transfer their energy to nearby magnetic molecules. d. a changing magnetic field causes a changing electric field.
Answers: 3
question
Physics, 23.06.2019 01:00
What ions are formed when hcl dissolves in water?
Answers: 1
question
Physics, 23.06.2019 02:10
Find the steady-state temperature at the center of the plate = /2, = /2) for sums of w from n=1 to n=19 (only odd values). find the value of n for which the change in /2, /2) is less than 1% from the value at the previous n. at this point, we consider the solution converged. does the value of the temperature at the center seem reasonable? in this part, the values of x and y are constant scalar values. you should produce a plot of the value of n on the horizontal and the estimate of the temperature at the center of the plate on the vertical. b. using the value of n (or larger) that resulted in convergence in part (a), create a contourf plot of the temperature distribution across the entire plate. use enough spatial subdivisions to create a useful plot. comment on the results. hint: you need to determine what “x” and “y” values to use to make your t matrix. i recommend using a different number of x and y values. use enough x and y values so that the plot is “smooth”.
Answers: 1
You know the right answer?
A mass spectrograph is used to measure the masses of ions, or to separate ions of different masses....
Questions
question
Mathematics, 05.05.2020 19:33
question
Mathematics, 05.05.2020 19:33
Questions on the website: 13722363