subject
Physics, 13.03.2020 22:47 jmullins3611

A three-phase wye-connected synchronous generator supplies a network through a transmission line. The network can absorb or deliver power while maintaining its terminal voltage constant. The four-pole, 60 Hz generator data rating are 40 MVA and 26 kV with a 0.85 p. u. reactance. The field current of the generator can be adjusted to regulate the excitation (induced) voltage from 0.75 to 1.5 times the rated voltage. The network voltage rating is 24 kV. The transmission line impedance and length are 0.07+j0.5 Ω/mi and 8 mi. (a) Calculate the generator induced voltage versus power factor, if the network voltage is at the rated value, and the bus absorbs the generator rated power. After this, plot the voltage regulation of the system versus the power factor. Use the induced voltage and network voltage for plotting the voltage regulation. The leading power factor varies from 0.5 to 1. What power factor corresponds to 10% regulation? (b) Plot the maximum power (power angle is 90°) versus induced voltage. Determine the required induced voltage that allows the safe transfer of maximum power from the generator to the network (not to exceed the generator rating). Assume that the network voltage is the same as in part (a). The excitation voltage is the variable.

ansver
Answers: 1

Another question on Physics

question
Physics, 22.06.2019 04:50
Describe the function of the endomembrane system? what organelles are involved?
Answers: 3
question
Physics, 22.06.2019 13:00
Which of the following are appropriate acceleration units?
Answers: 1
question
Physics, 22.06.2019 18:20
Object a has a length of 3 cm, a width of 2 cm, and a height of 4 cm. object b is dropped into a graduated cylinder. it displaces 19 ml of water. the volume of object a is: a: greater than the volume of object b b: less than the volume of object b c: equal to the volume of object b
Answers: 2
question
Physics, 22.06.2019 21:10
For the below questions, consider a consumer that consumes two goods, x and z with the following utility function. u with bar on top space equals space x to the power of 1 third end exponent z to the power of 2 over 3 end exponent suppose initial values for income and the prices of goods x and z are y equals 90, p subscript x equals space 10, and p subscript z equals 15 respectively, then the price of good x falls to syntax error from line 1 column 89 to line 1 column 100. unexpected '\'.. what is the magnitude of the total effect
Answers: 3
You know the right answer?
A three-phase wye-connected synchronous generator supplies a network through a transmission line. Th...
Questions
question
Mathematics, 30.11.2020 18:30
question
Mathematics, 30.11.2020 18:30
question
Advanced Placement (AP), 30.11.2020 18:30
Questions on the website: 13722367