subject
Engineering, 03.03.2022 03:30 alexciamartinez05

Very pure liquid water can be subcooled at atmospheric pressure to temperatures well below 0°C. Assume that 1 kg has been cooled as a liquid to −6°C. A small ice crystal (of negligible mass) is added to “seed” the subcooled liquid. If the subsequent change occurs adiabatically at atmospheric pressure, what fraction of the system freezes, and what is the final temperature? What is ΔS total for the process, and what is its irreversible feature? The latent heat of fusion of water at 0°C is 333.4 J⋅g−1, and the specific heat of subcooled liquid water is 4.226 J⋅g−1⋅°C−1. [

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water at 70°f and streams enter the mixing chamber at the same mass flow rate, determine the temperature and the quality of the exiting stream. 0 psia is heated in a chamber by mixing it with saturated water vapor at 20 psia. if both streams enters the mixing chamber at the same mass flow rate, determine the temperature and the quality of the existing system.
Answers: 2
question
Engineering, 04.07.2019 19:10
Plan an experiment to measure the surface tension of a liquid similar to water. if necessary, review the ncfmf video surface tension for ideas. which method would be most suitable for use in an undergraduate laboratory? what experimental precision could be expected?
Answers: 2
question
Engineering, 04.07.2019 19:10
Aplate of dimensions 3 m x 3 m is placed 0.37 mm apart from a fixed plate. the plate requires a force of 2n to move at speed of 45 cm/s. evaluate the viscosity of the fluid in between the plates
Answers: 3
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
Very pure liquid water can be subcooled at atmospheric pressure to temperatures well below 0°C. Assu...
Questions
question
Mathematics, 05.03.2021 01:00
question
Mathematics, 05.03.2021 01:00
question
Mathematics, 05.03.2021 01:00
question
Biology, 05.03.2021 01:00
Questions on the website: 13722367