2/23/2022 Open Book: Problem #1: Considering Figure 3.39 in textbook (see blackboard) calculate Cob and Csb using the following data for Vos = 1.0 V and Vs8 = 0.5 V. Calculate overlap capacitances between gate and source. = = N
o* = 1x1020 cm3 Na (Substrate) = 5x1018 cm3 NA (channel stop) = 1x1020 cm? = = = LM = 65 nm Lo = 10 nm Xi = 25 nm tox = 1.5 nm Vto = 0.5 V W = 5 um 1 = 0.05, Y = 30 nm Problem #2: Using device parameters of problem # 1, Using Hn = 300 cm?/V-s calculate the drain current for VGs = 1.2 V and Vos = 0.9 V and Vse =-1 V. = =

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Vibration monitoring this technique uses the noise or vibration created by mechanical equipment and in seme cases by plant systems to detemine their actual condtion. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:20
Asimple rankine cycle uses water as the working fluid. the water enters the turbine at 10 mpa and 480c while the condenser operates at 6 kpa. if the turbine has an isentropic efficiency of 80 percent while the pump has an isentropic efficiency of 70 percent determine the thermal efficiency
Answers: 1
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 18:20
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg