Engineering, 03.12.2021 21:30 stressedstudent6402
An air conditioner operates exactly as a refrigerator; it removes heat from a cold place (a bedroom, for example) and conveys it to a warmer place (usually the outside). Quantities of practical importance in understanding the efficiency of air conditioners are the rate of heat removal and the electric power input to the unit (i. e., the electric energy consumed per unit time). Find an expression for the coefficient of performance KKK of an air conditioner that has a rate of heat removal HHH and a power consumption PPP .
Answers: 3
Engineering, 04.07.2019 18:10
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
An air conditioner operates exactly as a refrigerator; it removes heat from a cold place (a bedroom,...
Mathematics, 20.09.2019 04:40
History, 20.09.2019 04:40
Mathematics, 20.09.2019 04:40
Mathematics, 20.09.2019 04:40
Biology, 20.09.2019 04:40
Geography, 20.09.2019 04:40
Mathematics, 20.09.2019 04:40
History, 20.09.2019 04:40
Geography, 20.09.2019 04:40
Physics, 20.09.2019 04:40
History, 20.09.2019 04:40
Social Studies, 20.09.2019 04:40
Biology, 20.09.2019 04:40
Social Studies, 20.09.2019 04:40