A retail store owner reports that the R-410A heat pump serv-ing the store is blowing cold air from time to time and not heating as it normally does. It runs constantly. The unit has a TXV. The technician turns the thermostat to the first stage of the heating mode. The air coming out of the air registers is cool; it feels like the return air. The outdoor unit is on the roof, and the indoor unit is in an attic crawl space. The thermostat is set with the first stage calling for heat; the outdoor unit should be on. The technician goes to the roof. The outdoor unit is running, but the gas line is cool. A gauge manifold is installed on the high and low sides of the system. The low side is operating in a vacuum, and the high-side pressure is 202 psig, which corresponds to the inside temperature of 70°F. This indicates that liquid refrigerant is in the condenser (the indoor coil). If the condenser pressure were 105 psig, well below the 202 psig corresponding to 70°F, it would indicate that the unit is low in refrigerant charge. What is the likely problem and the recommended solution?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 16:10
An electrical motor raises a 50kg load at a construct velencity .calculate the power of the motor, if it takes 40sec to raise the load through a height of 24m(take g =9.8n/g)
Answers: 2
You know the right answer?
A retail store owner reports that the R-410A heat pump serv-ing the store is blowing cold air from t...
Questions
Questions on the website: 13722363