subject
Engineering, 12.10.2021 02:00 marlesly87

Consider the process shown below in which a submersible pump at the bottom of a reservoir operates at steady-state pumpin water at a rate m = 9.0 lb/s to an elevated storage tank. Heat transfer between the pump and its surroundings is negligible. The velocity and temperature of the water do not change significantly between the pump inlet and the storage inlet. The water may be assumed to be incompressible fluid with density p=1.9 lb/ft® and constant specific heat Cu = 1 Btu/lb°R. The distance are zu = 20 ft and 24 = 18 ft. The pressures in the storage tank is given by P2 = 25.9 psi and the atmospheric pressure is given by Patm 14.5 psi. Assume g = 32.2 ft/s^2 Required:
What is the pressure at the inlet of the pump?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ariver flows from north to south at 8 km/h. a boat is to cross this river from west to east at a speed of 20 km/h (speed of the boat with respect to the earth/ground). at what angle (in degrees) must the boat be pointed upstream such that it will proceed directly across the river (hint: find the speed of the boat with respect to water/river)? a 288 b. 21.8 c. 326 d. 30.2
Answers: 3
question
Engineering, 04.07.2019 18:10
Shafts are machine elements that are used to a) carry axial loads b) direct shear loads c) transmit power d) rotate at constant speed e) none of the above circular and square shafts subjected to the same torque under the same circum behave a) the same way b) almost the same way
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
You know the right answer?
Consider the process shown below in which a submersible pump at the bottom of a reservoir operates a...
Questions
question
Spanish, 08.02.2021 05:40
question
Social Studies, 08.02.2021 05:40
question
Arts, 08.02.2021 05:40
Questions on the website: 13722367