subject
Engineering, 09.09.2021 19:50 shawk6230

3. Technician A says that air conditioning service machines are used exclusively with HFC-134a systems. Technician B says that refrigerant containing sealers should be recycled. Who is correct? A. Neither Technician A nor B B. Technician A C. Technician B D. Both Technicians And B

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
question
Engineering, 04.07.2019 18:20
Describe one experiment in which the glass transition temperature and melting temperature of a totally amorphous thermoplastic material can be determined. show the relevant experimental results in a diagram which should be properly annotated with the two temperatures clearly marked. what is likely to happen to the curve in the diagram if the amorphous polymer is replaced by a thermosetting type?
Answers: 2
question
Engineering, 04.07.2019 19:10
Asteel wire of 2 mm diameter is fixed between two points located 2 m apart. the tensile force in the wire is 250n, if its density of steel is given by 7830 kg/m3 the fundamental frequency of vibration hz? ?
Answers: 3
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
3. Technician A says that air conditioning service machines are used exclusively with HFC-134a syste...
Questions
question
History, 29.10.2020 18:30
question
English, 29.10.2020 18:30
question
Mathematics, 29.10.2020 18:30
question
Mathematics, 29.10.2020 18:30
question
Mathematics, 29.10.2020 18:30
question
Mathematics, 29.10.2020 18:30
question
Mathematics, 29.10.2020 18:30
question
History, 29.10.2020 18:30
question
Computers and Technology, 29.10.2020 18:30
Questions on the website: 13722363