subject
Engineering, 19.04.2021 15:10 miyocoilo07049

You are provided with the following information about a municipal wastewater treatment plant. This plant uses the traditional activated sludge process. There are 150,000 people in the community (their wastewater production is 225 L/day-capita, 0.1 kg BOD5/capita-day). The soluble BOD leaving the primary clarifier is 311 mg/L. The effluent standard is BOD5 = 20 mg/L and TSS = 20 mg/L. Suspended solids were measured as 4300 mg/L in a wastewater sample obtained from the biological reactor, which is 4200 cubic meters in volume. The suspended solids is 15,000 mg/L in the settled secondary sludge, 200 mg/L in plant influent, and 100 mg/L in the primary clarifier effluent. SRT is equal to 4 days. Required:
a. Draw a schematic of the plant and label all provided information on the diagram.
b. What is the plant's aeration basin’s hydraulic residence time (d)?
c. How many kg of secondary dry solids need to be processed daily from the treatment plants?
d. If the sludge wastage rate (Qw) is increased in the plant, will the solids retention time go up, go down, or remain the same?
e. Determine the F/M ratio in units of kg BOD / kg MLVSS-day.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 08:10
Which of the following is an easy way to remember the modified “x” tire rotation? a. nondrive wheels straight, cross the drive wheels b. drive wheels straight, cross the nondrive wheels c. drive wheels crossed, nondrive wheels straight d. drive wheels crossed, nondrive wheels crossed
Answers: 1
question
Engineering, 04.07.2019 18:10
The mass flow rate of the fluid remains constant in all steady flow process. a)- true b)- false
Answers: 1
question
Engineering, 06.07.2019 02:30
Define thermoplastic polymers and thermosetting polymers in terms of their structures, and (ii) describe briefly a process suitable for the production of products from each type of polymer.
Answers: 3
question
Engineering, 06.07.2019 04:10
Ir at sea level and 30°c and 50% relative humidity flows at a rate of 1 kg/s through a cooling coil that has an apparatus dewpoint of 10°c. the air leaves the coil at 15°c. determine the following: 3.1)- relative humidity of the air leaving the coil; 3.2)- moisture content of the air leaving the coil; 3.3)- sensible heat factor; 3.4)- total heat transfer rate; 3.5)- sensible heat transfer rate 3.6)- latent heat transfer rate
Answers: 1
You know the right answer?
You are provided with the following information about a municipal wastewater treatment plant. This p...
Questions
question
Mathematics, 31.12.2020 23:00
question
Mathematics, 31.12.2020 23:00
question
Computers and Technology, 31.12.2020 23:00
question
Computers and Technology, 31.12.2020 23:00
question
Computers and Technology, 31.12.2020 23:00
question
Mathematics, 31.12.2020 23:00
question
Computers and Technology, 31.12.2020 23:00
question
Mathematics, 31.12.2020 23:00
Questions on the website: 13722360