subject
Engineering, 08.04.2021 14:00 delaneynagle3368

Calculate the resistance of a copper wire 100m long having an area at 10mm​

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
question
Engineering, 04.07.2019 19:10
Agas contained within a piston-cylinder assembly e end nation about same energy states, 1 and 2, where pi 10 bar, v undergoes two processes, a and b, between the sam 0.1 m3, ui-400 kj and p2 1 bar, v2 1.0 m2, u2 200 kj: process a: process from 1 to 2 during which the pressure- volume relation is pv constant process b: constant-volume process from state 1 to a pressure of 2 bar, followed by a linear pressure-volume process to +20 0 state 2 kinetic and potential energy effects can be ignored. for each of the processes a and b, (a) sketch the process on p-v coordinates, (b) evaluate the work, in kj, and (c) evaluate process the heat transfer, in kj
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
question
Engineering, 04.07.2019 19:20
Air at a pressure of 1atm and a temperature of 40 c is in parallel flow over the top surface of a flat plate that is heated to a uniform temperature of 120 c. the plate has a length of 0.40m (in the flow direction) and a width of 0.15m. the reynolds number based on the plate length is 50, 000. what is the rate of heat transfer from the plate to the air? if the free stream velocity of the air is doubled and the pressure is increased to 10 atm what is the rate of heat transfer?
Answers: 2
You know the right answer?
Calculate the resistance of a copper wire 100m long having an area at 10mm​...
Questions
question
Health, 22.07.2021 17:30
question
Mathematics, 22.07.2021 17:30
question
Mathematics, 22.07.2021 17:40
Questions on the website: 13722363