10 pts) A wastewater is to be treated in a typical completely mixed activated-sludge system to a effluent BOD of 5 mg/L. The average flow rate is 18,300 m3/d. The influent BOD is 160 mg/L. The system is to operate at a concentration of 4,000 mg/L MLSS and 15 d mean cell residence time. The secondary clarifier is designed to thicken the sludge to 12,000 mg/L. Assume a yield coefficient of 0.5, an endogenous decay rate (kd) of 0.04 d-1 and the solids concentration in the effluent can be ignored. Design the secondary treatment system by determining: a) The volume of the aeration tank b) The flow rate of the WAS c) The flow rate of the RAS d) The sludge recycle ratio (RAS%) e) The mass of sludge wasted each day (in kg/day) f) Check the F:M

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
A-mn has a cubic structure with a0 0.8931 nm and a density of 7.47 g/cm3. b-mn has a different cubic structure, with a0 0.6326 nm and a density of 7.26 g/cm3. the atomic weight of manganese is 54.938 g/mol and the atomic radius is 0.112 nm. determine the percent volume change that would occur if a-mn transforms to b-mn.
Answers: 2
question
Engineering, 04.07.2019 19:10
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces.a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
question
Engineering, 04.07.2019 19:10
Ahelical coil spring has a mean diameter of 50 mm, a wire diameter of 5.5 mm and is wound with a pitch of 10 mm. the spring steel has an ultimate strength of 1250 mpa. find the force needed to compress the spring solid and the wire stress in this condition. state whether the spring will return to its initial length.
Answers: 1
You know the right answer?
10 pts) A wastewater is to be treated in a typical completely mixed activated-sludge system to a eff...
Questions
question
Biology, 02.06.2021 22:40
question
Mathematics, 02.06.2021 22:40
question
Mathematics, 02.06.2021 22:50
question
Biology, 02.06.2021 22:50
question
Mathematics, 02.06.2021 22:50
question
Mathematics, 02.06.2021 22:50
Questions on the website: 13722367