subject
Engineering, 03.04.2021 03:30 BlueLemonWater

The hot-wire anemometer.' A hot-wire anemome ter is essentially a fine wire, usually made of platinum, which is heated electrically and inserted into a flowingfluid. The wire temperature, which is a function of the fluidtemperature, fluid velocity, and the rate of heating, may bedetermined by measuring its electrical resistance. It is used for measuring velocities and velocity fluctuations in flow systems. In this problem we analyze the temperature distribution in the wire element. We consider a wire of diameter D and length 2L supported at its ends (z = -L and z =+L) and mounted perpendicular to an air stream. An electric current of density I amp/cm^2 flows through the wire, and the heat thus generated is partially lost by convection to the air stream and partially by conduction toward the ends of the wire. Because of their size and their high electrical and thermal conductivity, the supports are not appreciably heated by the current, but remain at the temperature TL, which is the same as that of the approaching air stream. Heat loss by radiation is to be neglected. Required:
Derive an equation for the steady-state temperature distribution in the wire, assuming that T depends on z alone.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 16:10
The force on a cutting tool are 2600n vertically downward and 2100 horizontal. determine the resultant force acting on the tool and the angle at which it acts.
Answers: 1
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Give heat transfer applications for the following, (i) gas turbines (propulsion) ) gas turbines (power generation). (iii) steam turbines. (iv) combined heat and power (chp). (v) automotive engines
Answers: 1
question
Engineering, 04.07.2019 18:20
Amixture of slurry and mud is to be pumped through a horizontal pipe of diameter 500 mm. the fluid behaves as a bingham plastic with a yield stress of 30 pa and viscosity 0.04 pa.s. describe the effects of the shear stress through a transverse section of the pipe by plotting the variation in shear stress and velocity profile: (i) just before the slurry starts to move (ii) as the slurry flows when the pressure gradient is double that in part (i)
Answers: 3
You know the right answer?
The hot-wire anemometer.' A hot-wire anemome ter is essentially a fine wire, usually made of platinu...
Questions
question
Mathematics, 17.10.2019 15:00
question
Mathematics, 17.10.2019 15:00
question
Chemistry, 17.10.2019 15:00
Questions on the website: 13722363