subject
Engineering, 25.03.2021 19:50 elijahbravo4334

In a process facility, you have two liquid streams with only methanol and water coming in from two separate processes. Stream 1 contains 80% of methanol by moles and Stream 2 contains 30% of methanol by moles. Your manager says you need to mix these together and flash it in a column. The temperature of operation is 400 K and you need to operate at a pressure that is nearly the average of the vapor pressures of methanol and water at 400 K. The VLE plot for methanol and water at 400 K is given to you. Required:
What is the vapor pressure of methanol and water? What is the operating pressure? You can round off the operating pressure to the nearest integer for further calculations

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 18:10
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg¡°c, oil . 120]
Answers: 1
You know the right answer?
In a process facility, you have two liquid streams with only methanol and water coming in from two s...
Questions
question
Mathematics, 26.02.2021 21:20
question
Mathematics, 26.02.2021 21:20
question
Mathematics, 26.02.2021 21:20
question
Health, 26.02.2021 21:20
Questions on the website: 13722363