A proposed laboratory scale cylindrical polymerization reactor to make high density polyethylene (HDPE) needs to be designed and constructed. The maximum design temperature and pressure of the reactor are 200 oC and 25 MPa, respectively. The reactor is used 4 times per day and must be designed for a minimum lifetime of 20 years. The inside diameter and wall thickness of the reactor are 300 mm and 10 mm, respectively. To meet safety regulations, a safety valve will be installed if the pressure exceeds 22 MPa, which will cause a maximum temperature drop of 220 oC in the valve region. The reactor must not plastically deform according the Von-Mises yield criteria, and should be designed following a leak-before-break approach. Determine the feasibility of making this reactor of available engineering alloys, and recommend a gasket material for the relief valve that meets the design and safety requirements. Consider at least three options for the reactor material even if you cannot find a suitable candidate. The reactor will be inspected periodically using a non-destructive technique capable of detecting 0.1 mm long internal flaws. Table 1 through 3 provide sample material properties you can use but you may use other data to broaden the choice of material. Assume a geometry factor of 1.5 for the stress intensity factor.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 18:10
Thermal stresses are developed in a metal when its a) initial temperature is changed b) final temperature is changed c) density is changed d) thermal deformation is prevented e) expansion is prevented f) contraction is prevented
Answers: 2
question
Engineering, 04.07.2019 18:10
The higher the astm grain-size number, the coarser the grain is. a)-true b)-false
Answers: 3
You know the right answer?
A proposed laboratory scale cylindrical polymerization reactor to make high density polyethylene (HD...
Questions
question
Business, 18.07.2019 19:30
Questions on the website: 13722363