subject
Engineering, 18.01.2021 14:00 rdemp6105

A copper bare wire, stranded, size 4/0 AWG is being tested in a laboratory (free air test), where the ambient temperature is 30 C (86 F). It is assumed that the damage temperature for this wire is 200 C. According to the results of previous tests, a factor h = 28 W/(㎡ K) can be used for a simplified first-order approximation. Using the simplified model described in class: a. Determine what would be the cable's ampere rating (IN) for a rated temperature of 65 C and the given ambient temperature
b. Determine the cable's minimum damage current (Id)
c. Determine the rt=Ky of the wire (approximated damage curve)
d. Plot the approximated damage curve in a log-log scale
e. Plot the "exact" (Approximation 1) damage curve in the same graph and compare. For which current value the two curves are practically equal?
f. Determine and plot the second approximation for the damage curve (T-Ind27t=K',d). Compare the plots of all the three damage curves

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Determine the damped natural frequencies and the steady state response of a decoupled damped forced two degrees of freedom system. 10ä1 + 2q1 20q1 10 cos t; 10q2 +4q2 + 40q2 10 cos t
Answers: 3
question
Engineering, 04.07.2019 19:10
What is the main objective of using reheat rankine cycle?
Answers: 3
question
Engineering, 04.07.2019 19:10
Plan an experiment to measure the surface tension of a liquid similar to water. if necessary, review the ncfmf video surface tension for ideas. which method would be most suitable for use in an undergraduate laboratory? what experimental precision could be expected?
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w