subject
Engineering, 05.01.2021 15:40 gabrieljerron

In a venturi nozzle flow, the inlet conditions are p1 = 08 x 103 kPa gauge and d1 = 100 mm and the outlet conditions are p2 = 0 kPa gauge and d2 = 50 mm. Find the flow rate of water. Assume CD = 0.98 for the venturi coefficient. a) (30) Neglect viscous effects (friction loss).
b) (10) Consider viscous effects.


In a venturi nozzle flow, the inlet conditions are p1 = 08 x 103 kPa gauge and d1 = 100 mm and the
In a venturi nozzle flow, the inlet conditions are p1 = 08 x 103 kPa gauge and d1 = 100 mm and the

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:20
Inspection for bearing condition will include: (clo4) a)-color b)-smell c)-size d)-none of the above
Answers: 1
question
Engineering, 04.07.2019 19:10
Abarometer contains mercury with a density of 13600 kg/m3. atmospheric conditions are 95.8 kpa and 20 °c at 20 °c, the vapor pressure of the mercury is 0.000173 kpa. the column of mercury will rise to a height of most nearly. select one: a)- 0.38 m b)- 0.82 m c)- 0.48 m d)- 0.72 m
Answers: 1
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
In a venturi nozzle flow, the inlet conditions are p1 = 08 x 103 kPa gauge and d1 = 100 mm and the o...
Questions
question
Mathematics, 03.03.2021 19:30
question
Biology, 03.03.2021 19:30
question
Mathematics, 03.03.2021 19:30
question
English, 03.03.2021 19:30
question
Mathematics, 03.03.2021 19:30
Questions on the website: 13722367