subject
Engineering, 27.12.2020 16:00 kishmarlewis

A wastewater treatment plant has a treatment capacity of 5000 m3/d with the average BOD of 150 mg/L, average total N of 40 mg/L, and average TSS of 350 mg/L in the primary settled effluent. The wastewater treatment process consists of primary settling, aeration tanks, secondary settling, and disinfection. The total suspended solid (TSS) in aeration tanks is 3500 mg/L. The settled sludge in the secondary settling tank is 10000 mg/L. The effluent regulation: BOD<10 mg/L, N<5 mg/L, and TSS<50 mg/L.
Calculation requirement:
1) Assume HRT in aeration tanks is 4 hrs, and the waste sludge flow rate from secondary settling tanks is 500 m3/d. Calculate the F: M ratio and SRT.
2) Discuss whether this system can achieve good BOD removal or N removal.
3) If you are asked to prolong SRT to 25 days, which engineering parameter you can adjust in this wastewater treatment system? Recalculate the Question (1) to make sure SRT is longer than 25 days.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Steel is coated with a thin layer of ceramic to protect against corrosion. what do you expect to happen to the coating when the temperature of the steel is increased significantly? explain.
Answers: 1
question
Engineering, 04.07.2019 18:10
Aflywheel accelerates for 5 seconds at 2 rad/s2 from a speed of 20 rpm. determine the total number of revolutions of the flywheel during the period of its acceleration. a.5.65 b.8.43 c. 723 d.6.86
Answers: 2
question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
You know the right answer?
A wastewater treatment plant has a treatment capacity of 5000 m3/d with the average BOD of 150 mg/L,...
Questions
question
English, 15.12.2020 17:30
question
Mathematics, 15.12.2020 17:30
question
Mathematics, 15.12.2020 17:30
question
Mathematics, 15.12.2020 17:30
question
Mathematics, 15.12.2020 17:30
Questions on the website: 13722363