Engineering, 26.12.2020 22:10 aubreyfoster
wide 100A service equipment panelboard is installed on the wall in the basement of a building. The Code requires that a space of atleast inches in width be maintained about this panelboard.
Answers: 1
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
Engineering, 04.07.2019 18:20
Aquick transition of the operating speed of a shaft from its critical speed will whirl amplitude. (a) increase (b) limit (c) not affect (d) zero
Answers: 2
Engineering, 04.07.2019 18:20
An engine runs on the ideal diesel cycle. the cycle has a compression ratio of 20 and a cutoff ratio of 2. the highest temperature in the cycle is 1200 k. if the heat into the system is 300 kj/kg of working fluid and using variable specific heats determine the work produced per mass of working fluid
Answers: 3
Engineering, 04.07.2019 19:20
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
wide 100A service equipment panelboard is installed on the wall in the basement of a building. The C...
Mathematics, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00
Biology, 07.02.2022 01:00
Arts, 07.02.2022 01:00
Geography, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00
Social Studies, 07.02.2022 01:00
Mathematics, 07.02.2022 01:00