subject
Engineering, 12.12.2020 17:00 bankskry

A 212 kV, three phase transmission line is 40 km long. The resistance per phase is 0.15? per km and the inductance per phase is 1.3263 mH per km. Find the voltage and power at the sending end and the voltage regulation and efficiency when the line is supplying a three phase load of 312 MVA at 212 kV at i) 0.8 power factor lagging, and ii) 0.8 power factor leading.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
During a steady flow process, the change of energy with respect to time is zero. a)- true b)- false
Answers: 2
You know the right answer?
A 212 kV, three phase transmission line is 40 km long. The resistance per phase is 0.15? per km and...
Questions
question
English, 21.05.2021 21:10
question
Mathematics, 21.05.2021 21:10
question
Mathematics, 21.05.2021 21:10
question
Chemistry, 21.05.2021 21:10
Questions on the website: 13722361