subject
Engineering, 16.10.2020 04:01 jawontestephens

A single phase, 50-KVA, 2400-240-volt, 60 Hz distribution transformer has the following parameters: • Resistance of the 2400-volt winding Ri=0.75 ohm
Resistance of the 240-volt winding R=0.0075 ohm
Leakage reactance of the 2400-volt winding X:=1 ohm
Leakage reactance of the 240-volt winding X2=0.01 ohm
Core loss resistance on the 2400 side Rc=733.5 ohms
Magnetizing reactance on the 2400 side X=4890 ohms
a. Draw the equivalent circuit referred to the high voltage side and referred to the low- voltage side. Label the impedances numerically.
b. The transformer is used as a step-down transformer at the load end of a feeder having impedance of (0.5+j2.0) ohms. Determine the voltage V. at the ending end of the feeder when the transformer delivers rated load at rated secondary voltage and 0.8 laggin power factor. Neglect the "exciting current" l. of the transformer (this is the current into the parallel Rc/jXm combination), which is another way of saying that you should use what we called in class the "approximate circuit #2).

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
question
Engineering, 04.07.2019 18:20
Inadequate stores control is not an obstacle to effective work order system. (clo4) a)-true b)-false
Answers: 3
You know the right answer?
A single phase, 50-KVA, 2400-240-volt, 60 Hz distribution transformer has the following parameters:...
Questions
Questions on the website: 13722367