Two wires of the same length and cross sectional area have finite but different E-field magnitudes inside them when the same current is flowing in each. The E-field magnitude in wire 1 is less than the field magnitude in wire 2. Select all of the following statements that are true based on this situation: The voltage drop in wire 1 is the same as the voltage drop in wire 2
The conductivity of wire 1 is less than the conductivity in wire 2
There is not enough information given in the problem to definitely determine the answer to the other 9 statements.
The power dissipation in wire 1 is more than the power dissipation in wire 2
The conductivity of wire 1 is more than the conductivity in wire 2
The conductivity of wire 1 is the same as the conductivity in wire 2
The power dissipation in wire 1 is less than the power dissipation in wire 2
The power dissipation in wire 1 is the same as the power dissipation in wire 2
The voltage drop in wire 1 is greater than the voltage drop in wire 2
The voltage drop in wire 1 is less than the voltage drop in wire 2

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
Two wires of the same length and cross sectional area have finite but different E-field magnitudes i...
Questions
question
Physics, 20.10.2020 01:01
question
Mathematics, 20.10.2020 01:01
question
Mathematics, 20.10.2020 01:01
question
Mathematics, 20.10.2020 01:01
question
Biology, 20.10.2020 01:01
question
Mathematics, 20.10.2020 01:01
Questions on the website: 13722362