subject
Engineering, 24.09.2020 15:01 19thomasar

We want to evaluate the usage of nitrogen in the ISU Unit Operations laboratory. We are concerned that if a release of nitrogen occurs, the oxygen level will be reduced below the 19.5% allowed by OSHA. The laboratory has a floor area of 4800 ft2 and a volume of 74,300 ft3 . The ventilation rate is 1 ft3 /min for each square foot of laboratory floor space. A. We currently use a gas cylinder to deliver nitrogen. This cylinder contains a volume of 1.76 ft3 of nitrogen. The nitrogen in a full cylinder is pressurized to 2500 psig. Nitrogen behaves as an ideal gas under these conditions. Calculate the concentration of oxygen in the room if the cylinder fails catastrophically. Assume that the nitrogen released by the cylinder displaces the air in the lab. Is the oxygen concentration acceptable for this case?
B. We are proposing to replace a gascylinder with a small nitrogen plant. The plant is capable of producing 19.3 SCFM of nitrogen. If the nitrogen is all released into the laboratory instead of into the process that uses it, estimate the concentration of oxygen in the lab due to this continuous release of nitrogen. Is this acceptable? What about the local concentration around the vicinity of the leak?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 12:10
On a average work day more than work place firs are reorted
Answers: 1
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
You are making beer. the first step is filling the glass carboy with the liquid wort. the internal diameter of the carboy is 15 in., and you wish to fill it up to a depth of 2 ft. if your wort is drawn from the kettle using a siphon process that flows at 3 gpm, how long will it take to fill?
Answers: 1
question
Engineering, 04.07.2019 18:20
Steam enters a converging nozzle at 3.0 mpa and 500°c with a at 1.8 mpa. for a nozzle exit area of 32 cm2, determine the exit velocity, mass flow rate, and exit mach number if the nozzle: negligible velocity, and it exits (a) is isentropic (b) has an efficiency of 94 percent
Answers: 2
You know the right answer?
We want to evaluate the usage of nitrogen in the ISU Unit Operations laboratory. We are concerned th...
Questions
question
Mathematics, 11.04.2020 00:04
Questions on the website: 13722367