subject
Engineering, 21.08.2020 16:01 carlossauceda0

Water that has a salt concentration of 12500 mg salt/Liter water is fed into a unit (U1) that can reduce the concentration of the salt. The outputs of this unit are a concentrated stream, and a diluted stream with salt concentration of 100 mg/L water. In order to obtain a water with a salt concentration of 500 mg/L water, a by-pass stream is used, where the by-pass stream is mixed with the diluted stream output of the unit (U1). If the fresh feed has a volumetric flow rate of 100L/min, and the concentrated stream accounts to 75% of the fresh feed.

Sketch fully detailed flow-chart of the process
Determine the NDF of at least three control volumes.
Calculate the concentration of the salt in the concentrated stream
Calculate the mass flowrate of water that has a salt concentration of 500 mg/L water
If the mass flowrate of water that has a salt concentration of 500 mg/L water is needed to be 340 g/min, calculate the mass flowrate of the fresh feed.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Heat is added to a piston-cylinder device filled with 2 kg of air to raise its temperature 400 c from an initial temperature of t1 27 cand pressure of pi 1 mpa. the process is isobaric process. find a)-the final pressure p2 b)-the heat transfer to the air.
Answers: 1
question
Engineering, 04.07.2019 18:20
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
question
Engineering, 04.07.2019 18:20
Apiston-cylinder device contains 0.1 m3 of liquid water and 0.9 m3 of water vapor in equilibrium at 800 kpa. heat is transferred at constant pressure until the temperature of water reaches 350 °c. determine (a) the quality of water at the initial state (b) the work associated with this process, (c) the heat associated with this process.
Answers: 2
question
Engineering, 04.07.2019 19:10
Asteam is contained in a rigid tank with a volume of 1 m3. initially, the pressure and temperature are 7 bar and 500 oc, respectively. the temperature drops due to cooling process. determine: (1) the temperature at which condensation begins in °c, (2) the fraction of the total mass that has condensed when the pressure decreased to 0.5 bar. (3) the volume in m3 occupied by saturated liquid at the final state?
Answers: 3
You know the right answer?
Water that has a salt concentration of 12500 mg salt/Liter water is fed into a unit (U1) that can re...
Questions
question
Mathematics, 10.01.2021 21:50
question
Mathematics, 10.01.2021 21:50
question
Mathematics, 10.01.2021 21:50
question
Mathematics, 10.01.2021 21:50
Questions on the website: 13722360