Engineering, 06.05.2020 01:40 ryevins3

The plant manager of a large industrial manufacturing facility plans to install a heat exchanger to use condenser-cooling water from its onsite steam power plant to pre-heat process cleaning water entering the manufacturing plant.
The process cleaning water, with a flow rate of 1800kg/hour is required to leave the counterflow simple single pass tube heat exchange at a temperature of 60°C having entered the exchanger at 20°C.
The condenser cooling water is available at an inlet temperature of 70°C and must be returned to the cooling system at a temperature no greater than 20°C.
I. Sketch the temperature distribution along the exchanger length for both counter flow and parallel flow heat exchanger configurations. Briefly explain why the counter flow arrangement is more effective per unit area.
II. Using the Log mean temperature Difference Method (LMTD) for an overall heat transfer coefficient of 0.5kW/m^2K and assuming a specific heat capacity of both fluids to be 4.181kJ/kg*K, complete the following for the counter flow heat exchanger:
i) State the assumption to be made when completing a LMTD analysis.
ii) Calculate the require flow rate of the condenser cooling water.
iii) Calculate the required heat dissipation rate achieved.
iv) Calculate the required heat transfer surface area for this installation.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 19:10
Agas is compressed from vi 0.3 m, p 1 bar to of v2 0.1 m3, p2--3 bar. pressure and volume are related linearly during the process. for the gas, find the work, in kj.
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
question
Engineering, 06.07.2019 03:10
Oxygen at 300 kpa and 400 k is in a closed system with an initial volume of 0.1 m3. is now compressed in a polytropic process, with exponent of n 1.2, to a temperature of 500 k. calculate: a) the boundary work done during the compression, in kj b) the heat transfer during the compression, in kj
Answers: 3
question
Engineering, 06.07.2019 04:10
Aheat pump that operates on the ideal vapor compression cycle with refrigerant-134a is used to heat water from 15°c to 45°c at a rate of 0.12 kg/s. the condenser and evaporator pressures are 1.4 and 0.32 mpa, respectively determine: (a) the power input to the heat pump
Answers: 1
You know the right answer?
The plant manager of a large industrial manufacturing facility plans to install a heat exchanger to...
Questions
question
Mathematics, 03.04.2021 01:00
question
Mathematics, 03.04.2021 01:00
question
Chemistry, 03.04.2021 01:00
question
Mathematics, 03.04.2021 01:00
question
English, 03.04.2021 01:00
question
Mathematics, 03.04.2021 01:00
Questions on the website: 13722367