A two-stage cascade refrigeration system is to provide cooling at -40ºC while operating with the high-temperature condenser at 1.6 MPa. Each stage operates on the ideal vapor-compression refrigeration cycle. The upper vapor compression refrigeration system uses water as its working fluid and operates its evaporator at 5ºC. The lower cycle uses refrigerant-134a as its working fluid and operates its condenser at 400 kPa. This system produces a cooling effect at 20 kJ/s. Determine (a) The heat transfer rate within the heat exchanger connecting the two refrigeration systems. (b) The mass flow rate of R-134a and water in their respective cycles, and (c) The required heat transfer area A inside the heat exchanger if the overall heat transfer coefficient U is 25 W/m2K . (25 pt.)

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
When at a point two solid phase changes to one solid phase on cooling then it is known as a) eutectoid point b) eutectic point c) peritectic point d) peritectoid point
Answers: 3
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
You know the right answer?
A two-stage cascade refrigeration system is to provide cooling at -40ºC while operating with the hig...
Questions
question
Mathematics, 22.01.2021 18:50
question
English, 22.01.2021 18:50
question
Mathematics, 22.01.2021 18:50
Questions on the website: 13722367