subject
Engineering, 06.05.2020 02:26 kadams3836

A co-flowing heat exchanger receives air at 800K and 15 MPa and water at 15oC and 100 kPa. The two flows exchange energy as they flow alongside each other to the exit, where the air should be cooled to 350K. Investigate the range of water flows necessary per kilogram per second of air flow and the possible water exit temperatures, with the restriction that the minimum temperature difference between the water and air should be 25oC. Include an estimation for the overall entropy generation in the process per kilogram of air flow. Support your analysis with graphical plots whenever possible to make your analysis easy to follow and understand. Assume that the heat exchanger loses heat to the environment which is at 4oC and estimate the range of that heat loss per kg/s of air flow in order not to violate the Second Law of Thermodynamic.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:10
The filament of an incandescent lamp has a temperature of 2000k. calculate the fraction of radiation emitted in the visible light band if the filament is approximated as blackbody
Answers: 2
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
A co-flowing heat exchanger receives air at 800K and 15 MPa and water at 15oC and 100 kPa. The two f...
Questions
question
Mathematics, 24.01.2020 00:31
Questions on the website: 13722361