Engineering, 25.04.2020 04:05 hanjonez

Question 5 (20 pts) The rated current of a three-phase transmission line is 300 A. The currents flowing by the line are measured with three current transformers each with ratio 250 : 5. What is the current you would measure at the secondary of each current transformer if rated current is flowing through each line. (of course the secondaries of the transformer must be part of closed circuits.) Consider the measured currents are exciting three over-current relays. Should the contacts of the relay close if rated current is circulating in the lines? If your answer is between no and yes, the current that the relay observes when rated current flows by the line must be the minimum pick-up current Ip. Hence, the tap position you should select, e. g., in the tap block of Fig. 1, must be equal o slightly greater than Ip for an over-current relay. Slightly greater when Ip is not an integer that matches the tap selection.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 18:10
Afour cylinder four-stroke in-line engine has a stroke of 160mm, connecting rod length of 150mm, a reciprocating mass of 3kg and its firing order is 1-3-4-2. the spacing between cylinders is 100mm. i. show that the engine is in balance with regard to the primary inertia forces and primary 3. a and secondary inertia couples. li determine the out of balance secondary inertia force ii. propose ways of balancing this out of balance force and discuss the challenges that will arise
Answers: 3
question
Engineering, 04.07.2019 18:20
Aheavily insulated piston-cylinder device contains 0.02 m3 of steam at 300 kpa and 200 °c. 1.2 mpa. d this process. team is now compressed in a reversible manner to a pressure of etermine the entropy change and the work done on the steam during this process
Answers: 1
You know the right answer?
Question 5 (20 pts) The rated current of a three-phase transmission line is 300 A. The currents flow...
Questions
question
Biology, 10.02.2021 01:30
question
Mathematics, 10.02.2021 01:30
question
Mathematics, 10.02.2021 01:30
question
Mathematics, 10.02.2021 01:30
question
Mathematics, 10.02.2021 01:30
question
Mathematics, 10.02.2021 01:30
question
Chemistry, 10.02.2021 01:30
Questions on the website: 13722367