subject
Engineering, 15.04.2020 20:45 booo1144

General Equations of Plane Strain Learning Goal: To become familiar with the general equations of plane strain used for determining in-plane principal strain, maximum in-plane shear strain, and average normal strain. The state of strain at a point has components of ϵx=380.0×(10−6), ϵy=−250.0×(10−6), and γxy=180.0×(10−6).Part A - Equivalent in-plane strains on the oriented element Determine the equivalent in-plane strains on an element rotated counterclockwise at an angle of θ = 60.0 ∘ . Find ϵx',ϵy', γxy' Express your answers, separated by commas, to three significant figures. Part B - In-plane principal strains on the oriented element Determine the in-plane principal strains on the oriented element. Find ϵ1, ϵ2. Express your answers, separated by a comma, to three significant figures. Part C - Maximum in-plane shear strain and average normal strain on the oriented element Determine the maximum in-plane shear strain and the average normal strain on the oriented element. Express your answers, separated by a comma, to three significant figures.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Which of the following ziegler nichols tuning methods the response of the controller to a step input should exhibit an s-shaped curve? a)-open loop mode b)-closed loop mode c)-both modes (open & closed) d)-none of the modes (open & closed)
Answers: 3
You know the right answer?
General Equations of Plane Strain Learning Goal: To become familiar with the general equations of pl...
Questions
Questions on the website: 13722363