subject
Engineering, 08.04.2020 04:40 zuleiny38

1) D Flip-Flop: • Plug in the 74LS74 D-type flip-flop and connect ground to pin 7 and 5V to pin 14 as usual. This is a two-circuit DIP. Referring to the 74LS74 pin-out diagram, choose one of the two D FFs on the chip and connect the input switches to the D and Preset inputs. Since the preset is negative-true logic input, make sure the switch is set to 1. Connect the pulse switches (the negative-true outputs) to the Clock and Clear inputs. The Q and Q' outputs should be connected to LED inputs. For this online version: • Go to the Memory folder to drop a D Flip-Flop onto the workspace. • Go to Wiring (or the shortcut menu) and drop two source pins (Square) onto the breadboard, one for the D input and the other for the Preset. Be sure to add labels. • Logisim is NOT negative true input. Adjust your circuit accordingly. • Go to the Input/Output folder and drop two "Buttons" (Square) onto the breadboard, one for the Clock (triangle on Flip Flip) and one for the clear. Be sure to add labels. • Go to the Input/Output folder, and drop two LED onto the workspace. Connect on to the Q output and one to the Q' output.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:10
Which of the following refers to refers to how well the control system responds to sudden changes in the system. a)-transient regulation b)- distributed regulation c)-constant regulation d)-steady-state regulation
Answers: 1
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 18:20
An open feedwater heater operates at steady state with liquid entering at inlet 1 with t? = 40°c and pl = 1 .2 mpa. water vapor att2-200°c and p2 = 1.2 mpa enters at inlet 2. saturated liquid water exits with a pressure of pa 1.2 mpa. neglect heat transfer with the surroundings and all kinetic and potential energy effects, determine the mass flow rate of steam at inlet 2 if the mass flow rate of liquid water at inlet 1 is given as 2 kg/s.
Answers: 3
You know the right answer?
1) D Flip-Flop: • Plug in the 74LS74 D-type flip-flop and connect ground to pin 7 and 5V to pin 14 a...
Questions
question
Social Studies, 18.07.2019 18:00
question
Spanish, 18.07.2019 18:00
question
Mathematics, 18.07.2019 18:00
Questions on the website: 13722363