subject
Engineering, 07.04.2020 16:20 hchvvhhv

Air from a workspace enters the air conditioner unit at 30C dry bulb and 20C wet bulb. The air leaves the air conditioner and returns to the space at 20C dry bulb and 6.5C dew point temperature. If there is any, the condensate leaves the air conditioner at the temperature of the air leaving the cooling coils. The volume flow rate of the air returned to the workspace is 600 m3/min. Atmospheric pressure is 101 kPa. Compute the heat transfer rate from the air in kW, and the mass flow rate of the condensate water, if any, in kg/h.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 19:10
An engine, weighing 3000 n, is supported on a pedestal mount. it has been observed that the engine induces vibration into the surrounding area through its pedestal at the maximum operating speed. determine the stiffness of the dynamic vibration absorber spring in (n/m) that will reduce the vibration when mounted on the pedestal. the magnitude of the exciting force is 250 n, and the amplitude of motion of the auxiliary mass is to be limited to 2 mm note: in this question type-in right numbers, no decimals, no fractions, no unit. approximate to right number if needed
Answers: 3
question
Engineering, 06.07.2019 03:20
1kg of water contained in a piston-cylinder assembly undergoes two processes in series from an initial state where the pressure is 3.0 bar and the temperature is 150°c process 1-2: the water is compressed isothermally to a volume of 0.25 m^3 with 120 kj of work being done to the system. process 2-3: the water is heated at constant volume to a final pressure of 10 bar. a. find the change in internal energy for the system. b. calculate the amount of heat transferred, in kj. c. sketch both processes on a t-v diagram. (196.33 kj/kg, 76.33 kj)
Answers: 1
You know the right answer?
Air from a workspace enters the air conditioner unit at 30C dry bulb and 20C wet bulb. The air leave...
Questions
question
Mathematics, 15.01.2021 19:00
question
Mathematics, 15.01.2021 19:00
question
Mathematics, 15.01.2021 19:00
question
Mathematics, 15.01.2021 19:00
question
Mathematics, 15.01.2021 19:00
question
Mathematics, 15.01.2021 19:00
Questions on the website: 13722360