subject
Engineering, 07.04.2020 01:05 xkxd13x

An array of electronic chips is mounted within a sealedrectangular enclosure, and colling is implemented by attaching analuminum heat sink (k=180 W/m*K). The base of the heat sinkhas dimensions of w1=w2=100mm, while the 6 fins are of thicknesst=10mm and pitch S=18mm. The fin length is Lf=50 mm, and thebase of the heat sink has a thickness of Lb=10mm.
If cooling is implemented by water flow through the heat sink, with u[infinity]=3 m/s and T[infinity]=17 C, what is the base temperatureTb of the heat sink when the power dissipation by the chips isPelec=1800W? The average convection coefficient for surfacesof the fins and the exposed base may be estimated by assumingparallel flow over a flat plate. Properties of the water maybe approximated as k=0.62 W/m*K, ν=7.73E-7 m2/s, andPr=5.2.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
question
Engineering, 04.07.2019 19:10
What are the major differences between injection molding and extrusion?
Answers: 2
You know the right answer?
An array of electronic chips is mounted within a sealedrectangular enclosure, and colling is impleme...
Questions
question
Mathematics, 09.06.2020 22:57
question
Social Studies, 09.06.2020 22:57
question
Mathematics, 09.06.2020 22:57
Questions on the website: 13722363