subject
Engineering, 28.03.2020 00:47 rainbowboy6055

When buttons or switches are pressed by humans for arbitrary periods of time, we need to convert a signal level to a pulse. In the following FSM, whenever the input L goes from low to high, the level-to-pulse converter produces a single pulse P, which is one clock period wide. Thus it is a synchronous rising-edge detector. Write a Verilog HDL for the following FSM. L=0 L- Level to pulse 00 Low input, Waiting for risg P0 01 Edge Detected! P=1 / 11 High input, Waiting for fall P=0 LEO CLK converter 1:0NoteDiagram cannot be explained

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 16:10
The force on a cutting tool are 2600n vertically downward and 2100 horizontal. determine the resultant force acting on the tool and the angle at which it acts.
Answers: 1
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
When buttons or switches are pressed by humans for arbitrary periods of time, we need to convert a s...
Questions
question
Mathematics, 30.11.2020 07:40
question
Mathematics, 30.11.2020 07:40
question
Mathematics, 30.11.2020 07:40
question
Mathematics, 30.11.2020 07:40
question
Mathematics, 30.11.2020 07:40
question
Mathematics, 30.11.2020 07:50
question
Computers and Technology, 30.11.2020 07:50
question
Mathematics, 30.11.2020 07:50
question
Mathematics, 30.11.2020 07:50
Questions on the website: 13722363