subject
Engineering, 25.03.2020 05:01 AdrienneFaye

A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -30 ℃ by rejecting its waste heat to cooling water that enters the condenser at 18 ℃ at a rate of 0.25 kg/s and leaves at 26 ℃. The refrigerant enters the condenser at 1.2 MPa and 65 ℃ and leaves at 42 ℃. The inlet state of the compressor is 60 kPa and -34 ℃ and the compressor is estimated to gain a net heat of 450 W from the surroundings. Determine the quality of the refrigerant at evaporator inlet.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aturning operation is performed with following conditions: rake angle of 12Β°, a feed of 0.35 mm/rev, and a depth of cut of 1.1 mm. the work piece is aluminum alloy 6061 with t6 heat treatment (a16061-t6). the resultant chip thickness was measured to be 1.0 mm. estimate the cutting force, fc. use shear stress of 207 mpa and coefficient of friction on the tool face of 0.6.
Answers: 1
question
Engineering, 06.07.2019 02:30
On solidification from a melt, the polymer polyethylene forms a semi-crystalline spherulite structure. (i) sketch an individual spherulite and label the amorphous and crystalline regions. (ii) draw a schematic to show the changes in specific volume with temperature during cooling from the melt, comparing it to the theoretical extremes of fully crystalline and fully amorphous (indicate tm and tg)
Answers: 2
question
Engineering, 06.07.2019 03:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg. a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 1
question
Engineering, 06.07.2019 04:10
Aheat pump that operates on the ideal vapor compression cycle with refrigerant-134a is used to heat water from 15Β°c to 45Β°c at a rate of 0.12 kg/s. the condenser and evaporator pressures are 1.4 and 0.32 mpa, respectively determine: (a) the power input to the heat pump
Answers: 1
You know the right answer?
A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerate...
Questions
Questions on the website: 13722364