subject
Engineering, 24.03.2020 04:07 rwerjekrryery6750

The liquid-phase reaction follows an elementary rate law and is carried out isothermally in a flow system. The concentrations of the A and B feed streams are 2 M before mixing. The volumetric flow rate of each stream is 5 dm 3 /min, and the entering temperature is 300 K. The streams are mixed immediately before entering. Two reactors are available. One is a gray, 200.0-dm 3 CSTR that can be heated to 77 C or cooled to 0 C, and the other is a white, 800.0-dm 3 PFR operated at 300 K that cannot be heated or cooled but can be painted red or black. Note that k 0.07 dm 3 /mol min at 300 K and E 20 kcal/mol.

a) Which reactor would and what conditions do you recommend? Explaining the reason for your choice. Back up your reasoning with calculations.

b) How long would it take to achieve 90% conversion in a 200 dm3 batch reactor with initial concentrations of A and B at 1 mol/L and operated at 77 Ā°C?

c) What would be your answer to part (b) if at 0 Ā°C?

d) What conversion would be obtained if the CSTR and PFR were operated at 300 K and connected in series? In parallel with 5 dm min of the mixture to each?

e) What can you say about the various reactor types based on the above?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
question
Engineering, 04.07.2019 18:10
Fluids at rest possess no flow energy. a)- true b)- false
Answers: 3
question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20Ā°c. air approaches the tube bank in the normal direction at 0Ā°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5Ā°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
You know the right answer?
The liquid-phase reaction follows an elementary rate law and is carried out isothermally in a flow s...
Questions
question
Mathematics, 09.03.2021 20:30
question
Mathematics, 09.03.2021 20:30
question
Mathematics, 09.03.2021 20:30
question
Mathematics, 09.03.2021 20:30
question
Health, 09.03.2021 20:30
Questions on the website: 13722367