subject
Engineering, 13.03.2020 22:14 brose0707

: You are working with a temperature sensor which produces a change in output voltage as temperature is increased. Between 0 – 50°C, the output voltage changes linearly from 0.2 – 0.7 V. You will amplify this voltage and adjust the offset using a linear signal conditioning circuit (a dc coupled amplifier), and connect its output to an 8-bit ADC with input range of 0 to 5V. (a) [8 points] If you preserve the entire 0 – 50°C range, what is the resolution of this system? What should the input/output relation be for the signal conditioning circuit so that the SQNR is maximized? (b) [7 points] If you require 0.01°C resolution at the ADC, you will need to sacrifice the range. If you want the ADC’s input voltage to be 2.5 V at 40°C, and a resolution of 0.01°C, what should the input/output relation be for the signal conditioning circuit? What is the range of the temperature?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Machinery that is a key part of the process and without which the plant or process cannot function is classifed as: (clo4) a)-critical machinery b)-essential machinery c)-general purpose machinery d)-none of the specified options.
Answers: 1
question
Engineering, 04.07.2019 18:10
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
question
Engineering, 04.07.2019 18:20
For each of the following process: a) sketch the p-v diagram, b)sketch t-s diagram, c) sketch t-v diagram, d) sketch the boundary work on one of the diagrams (a, b or c) and e) sketch the reversible heat transfer on one of the diagrams (a, b or c): 1- isobaric process from compressed liquid to superheated vapor 2- isothermal process from compressed liquid to superheated vapor 3- isentropic process from compressed liquid to superheated vapor
Answers: 3
You know the right answer?
: You are working with a temperature sensor which produces a change in output voltage as temperature...
Questions
question
Mathematics, 11.09.2019 23:30
question
Mathematics, 11.09.2019 23:30
Questions on the website: 13722363