subject
Engineering, 28.02.2020 00:49 michael11948

A signal suspected to be of the nominal form y(t) = 5 sin 1000 mV is measured by a first-order instrument having a time constant of 100 ms and K 1 V/V. It is then to be passed through a second-order amplifier having a K= 100 V/V, a natural frequency of 15,000 Hz, and a damping ratio of 0.8. What is the expected form of the output signal, y(t)? Estimate the dynamic error and phase lag in the output. Is this system a good choice here? If not, do you have any suggestions?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Avolume of 2.65 m3 of air in a rigid, insulated container fitted with a paddle wheel is initially at 264 k, 5.6 bar. the air receives 432 kj by work from the paddle wheel. assuming the ideal gas model with cv = 0.71 kj/kg • k, determine for the air the amount of entropy produced, in kj/k
Answers: 2
question
Engineering, 06.07.2019 02:30
A12 mm diameter shaft runs in a plain cylindrical bush 30 mm long that is located in an 18 mm diameter hole in a housing. the shaft-inner bush fit is h8 f and the outer bush-housing fit is h7-p6. make a fully cimensioned sketch of the bush with tolerances. find the maximum and minimum clearance or interference for both fits on the inner and outer diameters of the bush
Answers: 3
question
Engineering, 06.07.2019 04:10
Consider a power plant with water as the working fluid that operates on an ideal rankine cycle. it has a net power output of 45mw. superheated steam enters the turbine at 7mpa and 500°c (h=3411.4 kj/kg; s=6.8 kj/kg k) and is cooled in the condenser at a pressure of 10 kpa by running cooling water from a lake through the tubes of the condenser at a rate of 2000 kg/s. (a) show the cycle on a t-s diagram (a right schematic is fine - you do not need to calculate the temperatures at each point); (b)-determine the work done by the turbine and the pump in kj/kg; (c)-the mass flow rate of water used by the power plant; (d)-the thermal efficiency of the cycle; (e)-the temperature rise of the cooling water. assume the cooling water is incompressible with cp 4.18 kj/kg°c.
Answers: 3
question
Engineering, 06.07.2019 04:10
Aspherical thermocouple measurement errors a spherical thermocouple made of constantin transfer coefficient between the gas and the thermocouple is h used to measure the temperature of a gas. the heat 400 w/m2 k. calculate the maximum diameter d of the thermocouple if the thermocouple's measurement error should be w 23 within 5% of the initial temperature difference in 5 seconds. for constantin, k 8920 kg/m3, and c 410 j/kg. k.
Answers: 3
You know the right answer?
A signal suspected to be of the nominal form y(t) = 5 sin 1000 mV is measured by a first-order instr...
Questions
question
Mathematics, 18.11.2020 14:00
question
Chemistry, 18.11.2020 14:00
question
Mathematics, 18.11.2020 14:00
question
Mathematics, 18.11.2020 14:00
question
Mathematics, 18.11.2020 14:00
question
Health, 18.11.2020 14:00
Questions on the website: 13722367