subject
Engineering, 10.12.2019 04:31 jazzzzhands21

Aprocess fluid having a specific heat of 3500 j/kg∙k and flowing at 2 kg/s is to be cooled from 80 °c to 50 °c with chilled water, which is supplied at a temperature of 15 °c and a flow rate of 2.5 kg/s.

assuming an overall heat transfer coefficient of 2000 w/m2∙k, calculate the required heat transfer areas for the following exchanger configurations:

(a) parallel flow;

(b) counter flow;

(c) a 1-2 shell and tube exchanger with the water on the shell side.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
You know the right answer?
Aprocess fluid having a specific heat of 3500 j/kg∙k and flowing at 2 kg/s is to be cooled from 80 °...
Questions
question
Chemistry, 23.06.2019 10:00
question
Mathematics, 23.06.2019 10:00
Questions on the website: 13722363