subject
Engineering, 28.11.2019 03:31 bluevibe

Aplant has two identical standby generator units for emergency use. in the area of the generators, the normal noise level registers 81 dba on the sound-level meter with the generators turned off. when one generator switches on, the slm needle jumps to 83.6 dba. (a) perform calculations to determine what the dba reading will be when the second generator also turns on (so that both generators are on). (b) if both generators are on for a full 8-hour shift, will osha's pel be exceeded? will the al be exceeded? explain. (c) if one generator is on for half the shift and both are on for the other half, will the pel be exceeded? will the al be exceeded? explain. (d) in the absence of any plant background noise, what would be the sound level contributed by a single generator? by both generators? show calculations to explain.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
question
Engineering, 04.07.2019 19:10
An engine, weighing 3000 n, is supported on a pedestal mount. it has been observed that the engine induces vibration into the surrounding area through its pedestal at the maximum operating speed. determine the stiffness of the dynamic vibration absorber spring in (n/m) that will reduce the vibration when mounted on the pedestal. the magnitude of the exciting force is 250 n, and the amplitude of motion of the auxiliary mass is to be limited to 2 mm note: in this question type-in right numbers, no decimals, no fractions, no unit. approximate to right number if needed
Answers: 3
You know the right answer?
Aplant has two identical standby generator units for emergency use. in the area of the generators, t...
Questions
question
Mathematics, 30.08.2020 22:01
question
Mathematics, 30.08.2020 22:01
question
Mathematics, 30.08.2020 22:01
question
Mathematics, 30.08.2020 22:01
question
Mathematics, 30.08.2020 22:01
Questions on the website: 13722361