Engineering, 26.11.2019 23:31 sabianj0

An air-conditioning system takes in outdoor air at 10 celsius and 30% relative humidity at a steady rate of 45 m 3 /min, and conditions it to 25 celsus and 60% relative humidity. the outdoor air is first heated to 22 celsius in the heating section and then humidified by the injection of hot steam in the humidifying section. assume that the entire process takes place at a pressure of 100 kpa.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:10
Shafts are machine elements that are used to a) carry axial loads b) direct shear loads c) transmit power d) rotate at constant speed e) none of the above circular and square shafts subjected to the same torque under the same circum behave a) the same way b) almost the same way
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 06.07.2019 03:30
The catalogue for a refrigerant 22, four-cylinder, hermetic compressor operating at 29 r/s. a condensing temperature of 40°c and an evaporating temperature of -4°c shows a refrigeration capacity of 115 kw. at this operating point, the motor (its efficiency is 90 percent) draws 34.5 kw. the bore of the cylinders is 87 mm and the piston stroke is 70 mm. the performance data are based on 8°c of sub-cooling of the liquid leaving the condenser. compute (a) the actual volumetric efficiency and (b) the compression efficiency.
Answers: 2
You know the right answer?
An air-conditioning system takes in outdoor air at 10 celsius and 30% relative humidity at a steady...