Natural convection: air flows upward in a vertical heated cylindrical pipe. the fluid loses heat to the pipe walls as it flows upward. the incoming fluid temperature is th ('h' = "hot"), the pipe wall temperature is tc ('c' ="cold"). in the first case, the pipe radius is large enough that the boundary layers can be approximated as those for a vertical flat plate (sections 9.1 -9.4). find the nusselt number for the flow and then calculate the average convective heat transfer coefficient h and ý for pipe length h. in the second case, the pipe is thin enough that the entire pipe flow is fully developed (i. e., ignore the development length). the inflow is u(r) = umax [1 – (r/r.)2] with um = lap! /(84) with 14p! ~ p9b (th – tc). calculate the average convective heat transfer coefficient h and ġ for pipe length h. evaluate į versus d for both cases. now assume that as in the class example there is an array of tubes. there are now nx m tubes of diameter d in an l x w cross sectional area so nd x md = l x w or nxm= 6 ). to calculate the total heat transfer, multiply each ģ by the total number of tubes, n xm. then make an engineering estimate for the optimum value, if one exists. h . h iii)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 03.07.2019 23:20
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
question
Engineering, 04.07.2019 03:10
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
You know the right answer?
Natural convection: air flows upward in a vertical heated cylindrical pipe. the fluid loses heat to...
Questions
question
Mathematics, 12.07.2019 11:10
Questions on the website: 13722362