subject
Engineering, 11.11.2019 18:31 annethelusma25

Atwo-stage compression refrigeration system operates with refrigerant-134a between the pressure limits of 1 and 0.14 mpa. the refrigerant leaves the condenser as a saturated liquid and is throttled to a flash chamber operating at 0.5 mpa. the refrigerant leaving the low-pressure compressor at 0.5 mpa is also routed to the flash chamber. the vapor in the flash chamber is then compressed to the condenser pressure by the high pressure compressor, and the liquid is throttled to the evaporator pressure.

assuming the refrigerant leaves the evaporator as saturated vapor and both compressors are isentropic, determine

(a) the fraction of the refrigerant that evaporates as it is throttled to the flash chamber,

(b) the rate of heat removed from the refrigerated space for a mass flow rate of 0.25 kg/s through the condenser, and (c) the coefficient of performance.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
question
Engineering, 04.07.2019 18:10
Adouble-strand no. 60 roller chain is used to transmit power between a 13-tooth driving sprocket rotating at 300 rev/min and a 52-tooth driven sprocket. a) what is the allowable horsepower of this drive? b) estimate the center-to-center distance if the chain length is 82 pitches. c) estimate the torque and bending force on the driving shaft by the chain if the actual horsepower transmitted is 30 percent less than the corrected (allowable) power.
Answers: 3
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
You know the right answer?
Atwo-stage compression refrigeration system operates with refrigerant-134a between the pressure limi...
Questions
question
Biology, 13.07.2021 23:40
question
Chemistry, 13.07.2021 23:40
question
Physics, 13.07.2021 23:40
Questions on the website: 13722363