subject
Engineering, 05.10.2019 13:30 laurieburgess804

Consider a long, slender copper rod of diameter d = 1 cm and thermal conductivity k = 380 w/(m • °c), with one end thermally attached to a wall at 200°c. heat is dissipated from the rod by convection with a heat transfer coefficient h^ = 15 w/(m2 • °c). determine the heat transfer rate from the rod into the surrounding air at 7^ = 30°c.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 19:10
Analyze the factors that influence the choice between the following pairs of processes to make the products indicated: i) sand casting versus die casting of an electric-motor housing ii) thread rolling versus machining of a bolt for high-strength application. (co3/c5)
Answers: 3
question
Engineering, 04.07.2019 19:20
Air at a pressure of 1atm and a temperature of 40 c is in parallel flow over the top surface of a flat plate that is heated to a uniform temperature of 120 c. the plate has a length of 0.40m (in the flow direction) and a width of 0.15m. the reynolds number based on the plate length is 50, 000. what is the rate of heat transfer from the plate to the air? if the free stream velocity of the air is doubled and the pressure is increased to 10 atm what is the rate of heat transfer?
Answers: 2
question
Engineering, 06.07.2019 02:30
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
You know the right answer?
Consider a long, slender copper rod of diameter d = 1 cm and thermal conductivity k = 380 w/(m • °c)...
Questions
question
Mathematics, 16.12.2020 18:40
question
Mathematics, 16.12.2020 18:40
question
Mathematics, 16.12.2020 18:40
question
Chemistry, 16.12.2020 18:40
question
Mathematics, 16.12.2020 18:40
Questions on the website: 13722360