subject
Engineering, 03.10.2019 02:10 FavvBella84

Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105kpa (gauge) and a condensing pressure of 920 kpa (gauge). there is a sub-cooling of 3k with a superheat of the gas entering the compressor of 8k. the compressor is a four-cylinder reciprocating compressor with a bore of 67mm and a stroke of 57mm with an estimated capacity of 35kw. the compressor is directly coupled to an electric motor running at 1470rev/min and a power consumption of 19,5 kw. calculate: 1. the clearance volume efficiency if the compressor clearance is 3,6% 2. the actual volumetric efficiency 3. the compression efficiency when the mechanical efficiency is 85% and the motor efficiency 90%.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
You know the right answer?
Arefrigeration plant operates in pretoria on refrigerant r134a at an evaporator pressure of 105kpa (...
Questions
question
Mathematics, 22.06.2020 04:57
question
Mathematics, 22.06.2020 04:57
question
Mathematics, 22.06.2020 04:57
question
Computers and Technology, 22.06.2020 04:57
question
Social Studies, 22.06.2020 04:57
question
Mathematics, 22.06.2020 04:57
question
Mathematics, 22.06.2020 04:57
Questions on the website: 13722362