subject
Engineering, 14.09.2019 03:10 Ully4559

Alarge chamber contains air at 80 psia and 600 r at zero velocity. the air enters a converging- diverging nozzle which has an area ratio (exit/throat) of 3.0 a) what pressure must exist in the receiver for the nozzle to operate at its first critical point? the flow will reach sonic at the throat then decelerate to subsonic conditions at the exit b) what should the receiver pressure be for operating at the third critical point where supersonic flow exits the nozzle? if operating at the third critical point, what are the density and velocity of the air at the nozzle exit plane?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:10
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
question
Engineering, 06.07.2019 05:10
Air flows over a flat plate at a velocity of 3 m/sec and ambient conditions are, the pressure is 761 mm of hg and tempera- ture is 15°c. the plate is maintained at 85°c. if the length of the plate is 100 cm along the flow of the air, find out the heat lost by 50 cm of the plate which is measured from the trailing edge. plate width is 50 cm.
Answers: 1
You know the right answer?
Alarge chamber contains air at 80 psia and 600 r at zero velocity. the air enters a converging- dive...
Questions
question
Mathematics, 10.11.2020 17:00
question
Mathematics, 10.11.2020 17:00
question
Business, 10.11.2020 17:00
question
Mathematics, 10.11.2020 17:00
Questions on the website: 13722367