Anew counter flow heat exchanger was installed to replace the old heat exchanger. the new heat exchanger has an overall heat transfer coefficient of 280 w/mĀ²k. an ethylene glycol enters the tube side at 90Ā°c and exits at 70Ā°c while water enters the shell side at 25Ā°c and leaves at 40Ā°c. after a few months, the heat exchanger gives a fouling factor of 0.0005 mĀ².kw. if the surface area is 90 mĀ² and the specific heats at constant pressure for ethylene glycol and water are 2.43 kj/kg. k and 4.2 kj/kg. k respectively, determine: i)-the rate of heat transfer in the heat exchanger ( watts), and (ii) the mass flow rates of both working fluids (kg/s).

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 03:10
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
question
Engineering, 04.07.2019 18:10
Aplate clutch has a single pair of mating friction surfaces 250-mm od by 175-mm id. the mean value of the coefficient of friction is 0.30, and the actuating force is 4 kn. a) find the maximum pressure and the torque capacity using the uniform-wear model. b) find the maximum pressure and the torque capacity using the uniform-pressure model.
Answers: 3
question
Engineering, 04.07.2019 18:10
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
You know the right answer?
Anew counter flow heat exchanger was installed to replace the old heat exchanger. the new heat excha...
Questions
question
Mathematics, 31.05.2021 09:00
question
English, 31.05.2021 09:00
question
Mathematics, 31.05.2021 09:00
question
History, 31.05.2021 09:00
question
Mathematics, 31.05.2021 09:00
question
Biology, 31.05.2021 09:00
question
Mathematics, 31.05.2021 09:00
Questions on the website: 13722367