Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the eva porator at 50°c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c witha quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, (b) the mass flow rate of the refrigerant, (c) the heating load and the cop of the pump, and (d) the theoretical mini mum power input to the compressor for the same heating load.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 18:20
Select any two (2) areas of applications of chain-drive. (clo4) a)-permanent lubrication necessary b)-hydraulic forklift truck operation c)-rigging and heavy moving materials d)-relatively high maintenance costs e)-costlier than belt drives
Answers: 2
question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
You know the right answer?
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing h...
Questions
question
Mathematics, 22.10.2020 23:01
question
Arts, 22.10.2020 23:01
question
Health, 22.10.2020 23:01
question
Mathematics, 22.10.2020 23:01
question
Mathematics, 22.10.2020 23:01
question
Mathematics, 22.10.2020 23:01
question
Mathematics, 22.10.2020 23:01
question
Mathematics, 22.10.2020 23:01
Questions on the website: 13722361