The exhaust-gas temperature leaving a continuously operating furnace is 260 c, and a proposal is being considered to install a heat exchanger in the exhaust-gas stream to generate low-pressure steam at 105 c. the question to be investigated is whether it is economical to install such a heat exchanger, and, if so, to find its optimum size. the following data apply: flow of exhaust gas, 7.5 kg/s. specific heat of exhaust gas, 1.05 kj/(kg k). value of the heat in the form of steam, $1.50 per gigajoule. u value of heat exchanger based on gas-side area, 23 w/(m2 k). cost of the heat exchanger including installation based on gas-side area, $90 per square meter. interest rate, 8 percent. life of installation, 5 years. saturated liquid water enters heat exchanger at 105 c and leaves as saturated vapor. (a) develop the equation for the savings as a function of the area, expressed as a uniform annual amount.(b) what is the maximum permitted area if the exit-gas temperature is to be above 120 c in order to prevent condensation of water vapor from the exhaust gas? (c) use a seven-point fibonacci search and set up a table to simplify calculation of the optimum heat-transfer area.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 19:10
How to increase the thermal officiency of an ideal simple rankino cycle? among these methods, which one is the best and why?
Answers: 2
question
Engineering, 04.07.2019 19:10
Apressure vessel with an r/t 20 cannot be treated as thin walled vessel. a)-trune b)- false
Answers: 3
You know the right answer?
The exhaust-gas temperature leaving a continuously operating furnace is 260 c, and a proposal is bei...
Questions
question
Mathematics, 20.08.2019 06:10
question
Mathematics, 20.08.2019 06:10
question
Mathematics, 20.08.2019 06:10
question
Mathematics, 20.08.2019 06:10
question
Mathematics, 20.08.2019 06:10
Questions on the website: 13722363