In a dairy operation, milk at a flow rate of 250 l/h and a cow-body temperature of 38.6c must be chilled to a safe-to-store temperature of 13c or less. ground water at 10c is available at a flow rate of 0.72 m3/h. the density and specific heat of milk are 1030 kg/m3 and 3860 j/kg k, respectively. (a) determine the ua product of a counterflow heat exchanger required for the chilling process. determine the length of the exchanger if the inner pipe has a 50-mm diameter and the overall heat transfer coefficient is u 1000 w/m2 k. (b) determine the outlet temperature of the water. (c) using the value of ua found in part (a), determine the milk outlet temperature if the water flow rate is doubled. what is the outlet temperature if the flow rate is halved?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 16:10
An electrical motor raises a 50kg load at a construct velencity .calculate the power of the motor, if it takes 40sec to raise the load through a height of 24m(take g =9.8n/g)
Answers: 2
question
Engineering, 04.07.2019 18:10
Aloaded platform of total mass 500 kg is supported by a dashpot and by a set of springs of effective stiffness 72 kn/m. it is observed that when the platform is depressed through a distance x = 12.5 cm below its equilibrium position and then released without any initial velocity; it reaches its equilibrium position in the shortest possible time without overshoot. find the position and velocity of the loaded platform 0.10 sec. after its release. if a further load of 400 kg is added to the platform, find, i) the frequency of damped vibrations, and i) the amplitude of vibration after 2 complete oscillations, given that the initial amplitude is 15 cm.
Answers: 1
question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
You know the right answer?
In a dairy operation, milk at a flow rate of 250 l/h and a cow-body temperature of 38.6c must be chi...
Questions
question
Mathematics, 30.03.2020 19:38
question
Mathematics, 30.03.2020 19:38
question
Health, 30.03.2020 19:38
question
Mathematics, 30.03.2020 19:38
Questions on the website: 13722367